In the pilot (e,e'K) hypernuclear experiment, E89-009, the electrons associated with bremsstrahlung
dominated the background in the scattered electron spectrometer.
The idea to suppress the bremsstrahlung background is to use the difference of the angular distributions
between bremsstrahlung electrons and scattered electrons associated with the virtual photons which contributes to
kaon production.
The tilt of the Enge spectrometer off the bending plane of the Splitter magnet allows
us to avoid the extremely high rate electrons originating from bremsstrahlung and Mller scattering.
However, increasing the tilt angle, the number of the accepted virtual photons will decrease. Therefore,
we need to take following rates into account to optimize the tilt angle:
Originally we chose an Enge tilt angle of 4.5 degrees to optimize the best virtual photon flux
and bremsstrahlung electron rate. After the first readiness review, we performed
a more realistic optics study
based on the 3D magnetic field distribution of the Splitter calculated with TOSCA and
found the original Enge tilt angle (4.5 degrees) has still a significant acceptance to Mller electrons.
Figure 14 shows the electron scattering angle distributions at the target
for the 4.5 degree tilt and 4.5 cm offset in vertical direction of the spectrometer.
The blue dots and black dots show the electron distributions associated with virtual photons and
Mller scattering, respectively.
Since the beam energy is fixed, the scattering angle and momentum for M
ller
scattering electrons have one to one correspondence, and thus a ring shaped distribution
results from the M
ller scattering within momentum acceptance of the Enge spectrometer.
Using a RAYTRACE Monte Carlo simulation, the events which passed through the Enge spectrometer
without hitting the pole or collimators were selected. The magenta points are the electrons
associated with virtual photons which passed through the spectrometer and the
red points are for Mller electrons. Due to the effect of fringe fields, the 4.5 degree
tilt of the Enge spectrometer selects the electrons with scattering angle of 2.8 degrees (50 mr).
Figure 15 summarizes the RAYTRACE study for electron rates associated with bremsstrahlung,
Mller scattering and virtual photons. The rates depend on the vertical offset of the
Enge as well as its tilt angle.
From the figure, one can see, 1) bremsstrahlung electrons are more forward peaked than M
ller and VP,
2) M
ller scattered electrons peak around (
degrees , off
cm),
3) it is possible to select the Enge tilt parameters around (7
9 deg, 5
6 cm) to reduce
bremsstrahlung + M
ller rate to an acceptable level and to have as much as possible virtual photon yield.
Figure 16 shows the same plot as figure 14
for a tilt angle of 7.75 degrees.
The simulation was performed for vertical offsets of 5.5 and 6.0 cm. One can see that the
Enge acceptance is now out of Mller ring. If the real fringe field shape should differ
from this calculation, the Enge acceptance can be adjusted with hydraulic jacks.
Figure 17 shows the distribution at the sieve slit.
Densities of points are arbitrarily changed to see the distribution clearly.
Blue points are bremsstrahlung electrons, magenta the electrons associated with virtual photon,
green Mller scattered electrons, and red the electrons that
passed through the Enge spectrometer and were associated
with virtual photons. It can be seen that the tilt and shift of the Enge spectrometer shifts
the acceptance just
outside of M
ller electrons and ultra-high-rate bremsstrahlung electrons on the Splitter's bending plane.
The virtual photon yield is reduced by the larger tilt, but this factor could be still recoverable by increasing the beam current if the total rate at the Enge focal plane is less than the detectors' limit.
Figure 5 summarizes the Enge tilt angle dependences for the figure of merit of the virtual photon flux, background rates.